PT. INKALI
PT. INDONESIA NIKKA CHEMICALS
KARAWANG INTERNATIONAL INDUSTRIAL CITY ( KIIC )
Jl. Maligi II Lot E-3 , Karawang 41361
Telp. : (021) 8904209 , 8904309 , 8901602 , 8902469
Facs : (021) 8904390 , (0267) 643632
Branch Office : Istana Pasteur Regency, CRB – 103, Jl. Gunung batu Bandung 40175
Telp. (022) 6009170 , 6009171 Facs : (022) 6009171
MATERIAL SAFETY DATA SHEET
Date prepared : February 1, 2011
Revision: September16, 2011
Section 1 : Chemical Product and Company Identification
Product Name : NEOCRYSTAL BC - 75
Chemical Name or Synonym : Mixture of Sodium Poly acrylate and Carboxylic Acid Salt in
Water.
Manufacturer’s Name : PT. INKALI (INDONESIA NIKKA CHEMICALS)
Karawang International Industrial City ( KIIC )
Jl. Maligi II Lot. E – 3 Karawang 41361 , Indonesia.
Emergency Telephone Number : (021) 8904209 , 8904309 , 8902469 Fax (021) 8904390
Section 2 : Composition/Information on Ingredients
Hazardous Components CAS No. EINECS No. ACGIH’STLV Percentage
....................................................................................................................................................................…
No reportable quantities of hazardous ingredients are present.
Section 3 : Hazards Identification
Potential Health Effects
Inhalation : No hazard in normal industrial use.
Eye contact : Contact causes severe eye irritation.
Skin contact : Contact causes skin irritation.
Ingestion : May be harmful if swallowed.
Section 4 : First Aids and Measures
Inhalation : Move to fresh air, Seek medical attention if you feel unwell.
Eye contact : Rinse with water for at least 15 minutes. See a physician.
Skin contact : Rinse with water and soap. Remove contaminated clothes.
Ingestion : Rinse mouth and throat with water or milk. See a physician.
Section 5 : Fire-fighting Measures
Suitable fire extinguish media :
■Water , ■Foam , ■Carbon dioxide , ■Dry powder
Special exposure hazards : None
Special protective equipment for fire-fighters : None
Section 6 : Accidental Release Measures
Personal Precautions :
Not required
Environmental Precautions :
■ Do not allow to flow into drainage system.
□ Not required
Procedures for cleaning and recovery :
Remove with liquid-absorbing materials, (sand, sawdust, peat, etc.)
PT. INKALI
PT. INDONESIA NIKKA CHEMICALS
KARAWANG INTERNATIONAL INDUSTRIAL CITY ( KIIC )
Jl. Maligi II Lot E-3 , Karawang 41361
Telp. : (021) 8904209 , 8904309 , 8901602 , 8902469
Facs : (021) 8904390 , (0267) 643632
Branch Office : Istana Pasteur Regency, CRB – 103, Jl. Gunung batu Bandung 40175
Telp. (022) 6009170 , 6009171 Facs : (022) 6009171
Section 7 : Handling and Storage
Handling : Avoid contact with skin and eyes.
Avoid breathing dust.
Use only well-ventilated area.
Prevent damage to the container.
Storage : Store in sealed container and protect from direct sunlight.
Keep away from heat, sparks and flame.
Section 8 : Exposure Controls/Personal protection
Protective measures :
■ Impervious Gloves , ■ Safety Glasses or Goggles , ■ Respirators
Special protective measures : Local exhaust ventilation.
Other protective equipment : Eye-wash station , Emergency shower.
Section 9 : Physical and Chemical Properties
Appearance : Slightly Yellowish Transparent Liquid
Odor : Slightly
pH (Undiluted) : Approx. 10.
Melting point : Not Applicable
Boiling point : Approx 100 deg .C
Specific gravity : Approx. 1,15 (27 deg C)
Flash Point : None
Flammability : Not Flammable
Auto ignition temperature : None
Oxidizing property : None
Solubility : Ready soluble in water
Section 10 : Stability and Reactivity
Stability : ■ Stable, □ Unstable
Condition to be avoided : None
Substances to be avoided : None
Dangerous degradation products : None
Section 11 : Toxicological Data
Acute toxicity LC 50 : No data
Irritant effect on skin : No data
Irritant effect on eyes : No data
Section 12 : Ecological Data
Eco-toxic effects :
BOD 5 : 416 ppm ( 0.1 % sol )
COD (M n) : 895 ppm ( 0.1 % sol )
LC 50 (96hrs) : 2000 ppm < ( conforming OECD TG203 )
PT. INKALI
PT. INDONESIA NIKKA CHEMICALS
KARAWANG INTERNATIONAL INDUSTRIAL CITY ( KIIC )
Jl. Maligi II Lot E-3 , Karawang 41361
Telp. : (021) 8904209 , 8904309 , 8901602 , 8902469
Facs : (021) 8904390 , (0267) 643632
Branch Office : Istana Pasteur Regency, CRB – 103, Jl. Gunung batu Bandung 40175
Telp. (022) 6009170 , 6009171 Facs : (022) 6009171
Section 13 : Disposal Consideration
Waste disposal method :
In accordance with local authority regulations,
take to special waste incineration plant.
Section 14 : Transport Information
International regulation
UN Class : Not applicable
UN No : Not applicable
Packing Group : Not applicable
Not regulated by IATA
Section 15 : Regulatory Information
Marking according to EC diet ion : No data
National legal regulation : No data
CAS Number : Registered
Section 16 : Other Information
This information is based on our present state of knowledge.
It is intended to describe the product from the point of view of safety requirements and is not intended
to guarantee any particular properties.